Energy Mark

Product family

Motors, pumps and fans

Industrial motors, agricultural and submersible pumps, circulators, and ceiling, pedestal and table fans. How their energy test behaves, what Energy Mark reads early, and where each product is regulated.

The test

What the energy test looks like

Motors run at rated load until winding temperature stops rising, then efficiency is measured at several load points. Pumps and fans are measured across their duty curve.

The early read

What Energy Mark reads

  • Temperature rise curve during the heat run
  • Input power and current at each load point
  • Speed and slip
  • Flow and head for pumps, air delivery for fans

It predicts: Final temperature rise and efficiency, with a range, and the class it falls in. The certified result still comes from the full test.

Products

8 product categories in this family.

References show the test standard or labelling programme listed for each market. A dot means the category is not listed for that market.

Product categoryIndia (BEE)European UnionUnited StatesAustralia and NZ
General purpose industrial motorsIS 12615:2018, BEE Schedule 6Electric motors10 CFR Part 431·
Submersible pump setsIS 8034, IS 14220 and IS 9079, BEE Schedule 7Water pumps10 CFR Part 431·
Diesel engine-driven monoset pumps for agricultureIS 11501, IS 11170 and IS 11346, BEE Schedule 13···
Circulators·Circulators··
Industrial fans·Industrial fans··
Ceiling fansIS 374Air conditioners and comfort fans10 CFR Part 430·
Pedestal fansBEE Schedule 33Air conditioners and comfort fans··
Table and wall fansBEE Schedule 32Air conditioners and comfort fans··

Standards by market

The band always comes from the formula your market publishes.

India

IS 12615:2018 for motors, IS 8034, IS 14220 and IS 9079 for submersible pumps, IS 374 for ceiling fans, BEE Schedules 6, 7, 13, 32 and 33.

European Union

Ecodesign for electric motors, water pumps, circulators and industrial fans. Energy labelling for comfort fans.

United States

DOE 10 CFR Part 431 for electric motors and pumps, 10 CFR Part 430 for ceiling fans.

Other markets

The applicable national standard and its published formula.

Lab assessment

Find out if your test data can predict your ratings.

We look at your logger exports and completed tests, and tell you plainly whether Energy Mark can work in your lab.